Apple Watch · 6 min read
How accurate is Apple Watch VO2 max?
In Lambe's 2025 and 2026 maximal treadmill studies with breath analysis (28 and 35 mostly younger, mostly fit adults), Apple Watch read about 6 mL/kg/min low on average. In Apple's own validation of 221 older, less fit people, against a
What the Watch is estimating
VO₂ max is the most oxygen your body can use during exercise, in millilitres per kilogram per minute (mL/kg/min). Apple shows its estimate as Cardio Fitness in the Health app. A laboratory measures it directly: you run or cycle to exhaustion while a mask analyses the air you breathe.
The Watch does not do that. It estimates VO₂ max from how your heart rate responds to Outdoor Walk, Outdoor Run and Hiking workouts, with your age, sex, weight, height and any
Evidence: Apple: track your cardio fitness levels · Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021)
Five studies, compared
Each study compared the Watch's estimate with a reference test. A minus sign means the Watch read lower than the reference.
| Study | Who | Watch | Average | |
|---|---|---|---|---|
| Apple, white paper (2021) | 221 people in Apple's validation group; mean age 55; reference VO₂ max 29.7 on average | Series 4, watchOS 7 model | A projection from | +1.4 (SD 4.7) |
| Caserman et al. (2024) | 19 healthy adults aged 18 to 63, mean age 28 | Series 7, one outdoor run | Maximal cycling test with breath analysis | −4.5 (SD 7.8) |
| Lambe et al. (2025) | 30 healthy adults took part (mean age 32, half women); 28 analysed | Series 9, Ultra 2 and older models, watchOS 10 or later | Maximal treadmill test with breath analysis | −6.1 (SD 6.2) |
| Lambe et al. (2026) | 35 healthy adults analysed, mean age 23, about half women; 71% in the top fifth for fitness | Series 10, watchOS 11 | Maximal treadmill test with breath analysis | −6.3 (SD 6.1) |
| Tran et al. (2024) | 48 adults with complex congenital heart disease, mean age 33 | Several smartwatch makes; 79% Apple Watch | Cardiopulmonary exercise test with breath analysis | +3.1 |
Evidence: Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021) · Caserman et al. (2024): Apple Watch Series 7 VO2 max estimates against a lab test · Lambe et al. (2025): accuracy of Apple Watch VO2 max estimates · Lambe et al. (2026): accuracy of VO2 max estimates from Apple Watch Series 10 · Tran et al. (2024): smartwatch peak VO2 in complex congenital heart disease
Young, fit people: about 6 points low
The two Lambe studies tested mostly younger, mostly very fit adults on a treadmill with breath analysis. In 28 people the Watch read 6.1 mL/kg/min low on average; in 35 people on Series 10 it read 6.3 low. Caserman's 19 adults, tested on a bike, saw the Watch read 4.5 low.
In two small studies, the Watch read further below the lab, on average, in the fitter groups. In Caserman's maximal cycling study with breath analysis (19 adults), it read 12.0 low for the 5 people with excellent fitness and 3.4 low for the 11 with good fitness. In Lambe's 2026 maximal treadmill study with breath analysis (35 adults), an exploratory look at subgroups found the Watch read 7.8 low on average for the 25 people in the top fifth for fitness and 2.4 low for the 10 at or below the 70th percentile. The study's own test did not confirm that fitness explained the difference.
Evidence: Lambe et al. (2025): accuracy of Apple Watch VO2 max estimates · Lambe et al. (2026): accuracy of VO2 max estimates from Apple Watch Series 10 · Caserman et al. (2024): Apple Watch Series 7 VO2 max estimates against a lab test
Older or less fit people: slightly high
In Apple's own validation group of 221 people, who were older (mean age 55) and less fit, the Watch read 1.4 mL/kg/min high on average. That comparison was against a projection from
In Caserman's maximal cycling study with breath analysis (19 adults), the Watch read 3.8 high for the 3 people with poor fitness. In Tran's study of 48 adults with complex congenital heart disease, who did lab exercise tests with breath analysis while most wore an Apple Watch, smartwatches read 3.1 high on average. These groups are small, so treat the direction as more reliable than the exact size.
Evidence: Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021) · Caserman et al. (2024): Apple Watch Series 7 VO2 max estimates against a lab test · Tran et al. (2024): smartwatch peak VO2 in complex congenital heart disease
One reading can be off by about 12
Averages hide how far a single reading can land from the lab. Lambe's 2025 and 2026 maximal treadmill studies with breath analysis (28 and 35 adults) put the 95% limits of agreement at about 18 points low to 6 points high: roughly 12 either side of the average gap. In Apple's validation of 221 people against a
In Lambe's 2026 maximal treadmill study with breath analysis, the Watch put 5 of 35 people (14%) in the right fitness percentile band on the FRIEND registry's lab norms, and 12 more (34%) within one band. The other 18 (51%) were two or more bands out.
Evidence: Lambe et al. (2025): accuracy of Apple Watch VO2 max estimates · Lambe et al. (2026): accuracy of VO2 max estimates from Apple Watch Series 10 · Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021)
Read it as a trend
Repeated estimates from the same Watch are fairly steady. In Apple's validation group of 221 people, the median spread of one person's estimates was a standard deviation of 1.2 mL/kg/min, and an estimate agreed closely with one taken more than 28 days earlier (a reliability score of 0.86 out of 1). In Tran's 48 heart patients, changes between two lab tests at least a year apart were closely correlated with changes in the smartwatch readings.
That makes the direction of your number over months more useful than any single value. The 2026 Lambe study notes that how Apple Watch estimates relate to real changes over time is still unclear, and suggests its estimates may still show broad trends for general fitness. Wear the Watch through the day, record outdoor walks, runs or hikes regularly, and keep your age, weight and medicines up to date in Health.
Evidence: Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021) · Tran et al. (2024): smartwatch peak VO2 in complex congenital heart disease · Lambe et al. (2026): accuracy of VO2 max estimates from Apple Watch Series 10
Base reads Apple's number; it does not change it
Base counts your zone 2 minutes from recorded Apple Watch workouts. The VO₂ max estimate comes from Apple Health. Base does not measure VO₂ max, and it does not adjust or correct Apple's estimate.
Track both: your weekly zone 2 minutes in Base, and the trend in Cardio Fitness over months.

Sources & further reading
Source types matter:
- Apple: track your cardio fitness levelsOfficial product documentation · published September 14, 2026
- Apple: Using Apple Watch to Estimate Cardio Fitness with VO2 max (2021)Manufacturer white paper · May 2021 · Apple's design and validation data
- Caserman et al. (2024): Apple Watch Series 7 VO2 max estimates against a lab testIndependent validation study · 19 adults · maximal cycling test with breath analysis
- Lambe et al. (2025): accuracy of Apple Watch VO2 max estimatesIndependent validation study · 30 adults, 28 analysed · maximal treadmill test with breath analysis
- Lambe et al. (2026): accuracy of VO2 max estimates from Apple Watch Series 10Independent validation study · 40 adults, 35 analysed · maximal treadmill test with breath analysis
- Tran et al. (2024): smartwatch peak VO2 in complex congenital heart diseaseProspective study · 48 adults with congenital heart disease · mixed smartwatches, 79% Apple Watch
Count your minutes. Watch the trend.
Base counts the zone 2 minutes in your recorded Apple Watch workouts and shows your week on iPhone and Apple Watch. Apple Health keeps the VO₂ max estimate; Base does not change it. Watch the two together over months. Your
Explore the benefits and science · See how Base works · Read the privacy notice